@@ -1,10 +1,347 @@
|
|
|
-V0.0.2
|
|
|
+# V1.2.0 (2025-06-16 - 2025-06-26)
|
|
|
|
|
|
-New and improved:
|
|
|
-1. Add NTP time sync
|
|
|
-2. Add Changes log in firmware upgrade page
|
|
|
-3. Add power data manual export in web and auto export in smtp mail
|
|
|
+**New Features**
|
|
|
+- Added SNMP interface for retrieving F407 power information.
|
|
|
|
|
|
-Fixes and enhancements:
|
|
|
-1. Increase the data quantity in power history query, upper limit 7 days
|
|
|
-2. Fix the not working bug in Overall Status History/Device History/Power Chart
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed GPIO conflict for dry contact sensors on the LCD screen.
|
|
|
+- Resolved issue with batch threshold setting failure.
|
|
|
+- Fixed SNMP GETNEXT command errors.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized three-phase engineering configuration parameters.
|
|
|
+- Streamlined firmware by removing unused functional modules.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.1.9 (2025-06-01 - 2025-06-15)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Added support for displaying CO₂ sensor data.
|
|
|
+- Added Bootloader secure jump verification for 4-channel boards.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed sensor disconnection issue caused by rapid plugging/unplugging.
|
|
|
+- Resolved MQTT device number type error.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized alarm interface interaction logic.
|
|
|
+- Reduced Websocket push data volume.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.1.8 (2025-05-16 - 2025-05-31)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Added batch threshold setting function for F407 sensors.
|
|
|
+- Supports hot-switching between three-phase/single-phase operating modes.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed GPIO conflict during RGB meter head initialization.
|
|
|
+- Resolved SNMP sensor list retrieval exception.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized QT startup page loading speed.
|
|
|
+- Added Bootloader upgrade file verification mechanism.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.1.7 (2025-05-01 - 2025-05-15)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Supports dry contact alarms for multiple sensors.
|
|
|
+- Added channel timed Websocket push function.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed LCD data display conflict for multiple sensors.
|
|
|
+- Solved crash issue caused by MQTT connection failure.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized 4G activation configuration, reducing CPU usage.
|
|
|
+- Shortened sensor offline determination time (3 timeouts).
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.1.6 (2025-04-16 - 2025-04-30)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Supports circuit breaker status detection.
|
|
|
+- Added support for 4-channel / 1-channel self-locking control boards.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed three-phase phase loss detection anomaly.
|
|
|
+- Resolved NTP synchronization failure for IP meter heads.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized Modbus TCP communication timeout handling.
|
|
|
+- Reduced memory usage for historical record storage.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.1.5 (2025-04-01 - 2025-04-15)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Supports 125A engineering configuration.
|
|
|
+- Added dual live wire version for three-phase input to single-phase output.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed Web threshold upper limit (max 999999).
|
|
|
+- Solved QT interface misalignment issue for three-phase data display.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized dual live wire power factor calculation algorithm.
|
|
|
+- Simplified product file reading logic.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.1.4 (2025-03-16 - 2025-03-31)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Supports reverse control for magnetic latching relays.
|
|
|
+- Added hardware support for 7-channel / 3-channel boards.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed dual live wire threshold enable anomaly.
|
|
|
+- Resolved STS control logic conflict.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Unified parameter configuration for DC control boards.
|
|
|
+- Optimized stability of cascaded data reading.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.1.3 (2025-03-01 - 2025-03-15)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Supports SNMP power threshold management.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed crash issue on legacy three-phase control boards.
|
|
|
+- Resolved IP meter head database access conflict.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized synchronization between channel control and web data.
|
|
|
+- Reduced EEPROM write frequency on DC control boards.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.1.2 (2025-02-16 - 2025-02-28)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Supports App-side version number upload.
|
|
|
+- Added dual-stack (IPv4/IPv6) detection for 4G networks.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed Bootloader verification failure issue for new 5-channel/4-channel boards.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized QT interface layout, unified sensor unit display.
|
|
|
+- Compressed F407 basic data structure (256 → 92 bytes).
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.1.1 (2025-02-01 - 2025-02-15)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Added web configuration items for 4G-related functions.
|
|
|
+- Added dual live wire single-phase control matching logic.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed WiFi SNMP protocol unavailability.
|
|
|
+- Solved stack overflow issue caused by frequent three-phase data reading.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized Websocket push cycle (0.5 seconds/push).
|
|
|
+- Added display support for CO₂ sensors.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.1.0 (2025-01-16 - 2025-01-31)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Supports STS (Static Transfer Switch) temperature monitoring.
|
|
|
+- Added magnetic latching relay control logic.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed upgrade function anomaly on single-phase control boards.
|
|
|
+- Resolved STS Modbus communication out-of-bounds issue.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized Bootloader jump verification process.
|
|
|
+- Reduced stack memory usage on three-phase control boards.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.0.9 (2025-01-01 - 2025-01-15)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Added network reset function (hold Up/Down keys to restore default configuration).
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed dual live wire project configuration error.
|
|
|
+- Resolved QT interface sensor unit display anomaly.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized MQTT data structure (power status upload).
|
|
|
+- Streamlined firmware size by removing redundant modules.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.0.8 (2024-12-16 - 2024-12-31)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Supports channel "Monitor Only" mode.
|
|
|
+- Added 4G SMS alarm push function.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed GPIO conflict between RGB meter head and LCD screen.
|
|
|
+- Resolved INI configuration deadlock issue.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized 4G network detection mechanism.
|
|
|
+- Shortened sensor serial port read timeout to improve response speed.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.0.7 (2024-12-01 - 2024-12-15)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Supports three-phase total detection function.
|
|
|
+- Added dynamic DHCP allocation for Modbus TCP addresses.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed leak sensor display error on military 8-inch screen.
|
|
|
+- Solved QT interface rotation direction anomaly.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized communication efficiency between QT and PDU message queues.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.0.6 (2024-11-16 - 2024-11-30)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Added circuit breaker trip alarm function.
|
|
|
+- Supports control board firmware upgrade via web interface (includes QR code generation).
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed threshold import exception.
|
|
|
+- Resolved sensor data garbled text issue on IP meter heads.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized packaging scripts for new hardware compatibility.
|
|
|
+- Refactored Web interface layout, fixed display misalignment.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.0.5 (2024-11-01 - 2024-11-15)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Added configuration file import/export interfaces.
|
|
|
+- Supports configuring meter face maximum values for voltage/current/power.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed memory leak in three-phase input to single-phase output configuration.
|
|
|
+- Resolved NTP synchronization failure.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Removed database dependency on `product_id` to avoid configuration change anomalies.
|
|
|
+- Added slave temperature sensor data display to IP meter heads.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.0.4 (2024-10-16 - 2024-10-31)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Supports SNMP TRAP function (sensor/power overload alarms).
|
|
|
+- Added Websocket encrypted connection and HTTPS access.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed crash issue caused by cascaded data anomalies.
|
|
|
+- Resolved SNMP configuration invalid error.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized upgrade script push logic.
|
|
|
+- Sensor history records now displayed in reverse chronological order (last 60 entries).
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.0.3 (2024-10-01 - 2024-10-15)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Supports Modbus TCP cascading communication and dynamic slave scanning.
|
|
|
+- Integrated Libcurl for email alarm functionality.
|
|
|
+- Added NTP time synchronization function.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed time zone setting error.
|
|
|
+- Resolved database anomalies caused by configuration file ID changes.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized NTP interface to support both IP and domain name modes.
|
|
|
+- Refactored thread management interface.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.0.2 (2024-10-01 - 2024-10-07)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Control boards support firmware upgrade logic.
|
|
|
+- Added time range restriction function for database queries.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed high CPU usage when no channels are scanned.
|
|
|
+- Solved three-phase total data reading anomaly.
|
|
|
+- Fixed single-phase/DC power consumption calculation error.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Increased maximum voltage display limit to 500V.
|
|
|
+- Optimized configuration file import/export interfaces.
|
|
|
+- Resolved button display issues caused by XML limitations.
|
|
|
+- Improved sensor historical status storage logic.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.0.1 (2024-09-16 - 2024-09-30)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Supports synchronized three-phase data display on QT screen.
|
|
|
+- Added power consumption reset function for DC/single-phase devices.
|
|
|
+- Added watchdog mechanism to enhance system stability.
|
|
|
+- Supports independent configuration for DC overload alarm/action.
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed DNS configuration error.
|
|
|
+- Solved issue where alarm threshold flags were not updated after reset.
|
|
|
+- Fixed single-phase/DC total power consumption calculation error.
|
|
|
+- Resolved file export function bug.
|
|
|
+- Optimized database query efficiency (default time range reduced to 1 week).
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Optimized power consumption calculation algorithm.
|
|
|
+- Changed meter head alarm identifiers from `ABC` to `L123`.
|
|
|
+- Adapted to dry contact sequence mapping requirements.
|
|
|
+- Web interface upgraded to version 9.28, supporting Alibaba Cloud MQTT.
|
|
|
+
|
|
|
+------------------------------------------------------------------------------
|
|
|
+
|
|
|
+# V1.0.0 (2024-09-01 - 2024-09-15)
|
|
|
+
|
|
|
+**New Features**
|
|
|
+- Adapted to Alibaba Cloud MQTT service.
|
|
|
+- Supports CO₂ sensor data reading.
|
|
|
+- Added sensor history record query interface.
|
|
|
+- Customized Web pages for clients (separated by user directory).
|
|
|
+
|
|
|
+**Bug Fixes**
|
|
|
+- Fixed sensor historical record storage anomaly.
|
|
|
+- Solved three-phase frequency calculation error.
|
|
|
+- Fixed power consumption reset function failure.
|
|
|
+- Fixed dual-head sensor threshold setting anomaly.
|
|
|
+- Resolved delay issue caused by switch detection board scan timeout.
|
|
|
+
|
|
|
+**Optimizations**
|
|
|
+- Merged RAM/ROM checks into a unified interface.
|
|
|
+- Optimized temperature/humidity sensor threshold retrieval logic.
|
|
|
+- Updated Web to version 9.28.
|
|
|
+- Added null checks to prevent out-of-bounds crashes.
|